BRDNC - ULTRA LAST 833, 0915

  • MSDS: BRDNC
  • Manufacturer: MANTEK DIV OF NCH CORP
  • Product Name: ULTRA LAST 833, 0915
  • National Stock Number: 7930-00N034358
Product Identification

Product ID:ULTRA LAST 833, 0915
MSDS Date:08/22/1991
FSC:7930
NIIN:00N034358
MSDS Number: BRDNC

Responsible Party
MANTEK DIV OF NCH CORP
IRVING, TX 75015
US

Emergency Phone: 214-438-1381

Info Phone: 214-438-1381

Preparer: RICHARD STOLLEY

Cage: GO368

Contractor
NCH CORP
152170 IRVING, TX 75015-2170 US

Telephone: 972-438-0563

Cage: 20913

Ingredients

ETHANE,1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE).

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 40%

OSHA PEL 350 PPM;450 STEL

ACGIH TLV: 350 PPM;450 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


2-PYRROLIDINONE, 1-METHYL-; (N-PYRROLIDONE).

CAS: 872-50-4

RTECS: UY5790000


CYCLOHEXENE, 1-METHYL-4-(1-METHYLETHENYL)-, (R)-;

CAS: 5989-27-5

RTECS: GW6360000


NO SMOKING IN AREA OF USE. DO NOT USE IN GEN

RTECS: 9999999ZZ


UV RADIATION MAY CAUSE FORMATION OF HCL AND/OR

RTECS: 9999999ZZ


INDOORS, TURN OFF AIR CONDITIONERS &/OR HEATING

RTECS: 9999999ZZ


POLYVINYL ALCOHOL, OR EQUIVALENT).

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: MAJOR POTNTL RTE OF
EXPOS W/EFTS OBSERVED SUCH AS DIZZ, DROW, & THROAT IRRIT. UNCON &
DEATH POSS IN CASES OF MAX OVEREXP. SKIN:IRRIT & REDDEN CAN OCCUR.
INGEST:LG QTY CAN CAUSE DIZZ, NAU S, CRAMPS, VOMIT, DIARR & MAY BE
ABSORBED. ASPIR OF MATL INTO LUNGS CAN LEAD TO CHEM PNEUM. EYE: CAN
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CAUSE IRRIT, REDDENING & LACRIMATION
(TEARING). CHRONIC: EYE: CHRONIC OVEREXP CAN LEAD TO TISSUE DAM &
POSS BLINDNESS. SKIN: COULD LEAD TO DERM. INHAL: CAN EVENTUALLY
LEAD TO KIDNEY, LIVER, B LOOD SYS & CNS DAM. (TARGET ORGANS).
CHLOROCARBON MATLS HAVE PRDCD SENSIT OF MYOCARDIUM (SUPP DATA
Medical Cond Aggravated by Exposure:PRE-EXISTING LIVER, KIDNEY, SKIN OR
EYE DISORDERS MAY BE AGGRAVATED UPON OVEREXPOSURE.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR.IF BRTHG HAS STOPPED, ADMINISTER
ARTF RESP.CALL A PHYS. EYE:FLUSH IMMED W/WATER FOR @ LST 15 MIN.IF
IRRIT PERSISTS, CALL A PHYS. SKIN:REMOVE CONTAMD CLTHG & SHOES.
WASH W/SOA P & WATER. WASH CONTAMD CLTHG BEFORE REUSE. INGEST:DO
NOT INDUCE VOMIT.CONT PHYS/EMER MED FACILITY IMMED. NOTES TO
PHYS:ADRENALIN SHOULD NEVER BE GIVEN TO PERSONS OVEREXPOSED TO
1,1,1-TRICHLOROETHANE.

Fire Fighting

Flash Point Method:TCC
Flash Point:175F,79C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL, WATER SPRAY.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CONCENTRATED VAPORS CAN BE IGNITED BY
HIGH INTENSITY ENERGY SOURCES. THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL AND PHOSGENE .

Accidental Release

Spill Release Procedures:EVACUATE AREA, VENT, & AVOID BRTHG VAPS. DIKE
AREA TO CNTN SPILL. CLEAN UP AREA (WEAR PROT EQUIP) BY MOPPING OR
W/ABSORB MATL & PLACE IN CLSD CONTRS FOR DISP. AVOID CONTAM OF
GROUND & SURF WATERS. DO NOT FLUSH TO SEWER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORAGE TEMP: 100F. STORE IN TIGHT
SEALED, LBLD CONTRS IN COOL, DRY, WELL-VENTD AREA. PVNT WATER/MOIST
AIR FROM ENTERING STORAGE/TRANSFER.
Other Precautions:DO NOT CUT/WELD ON EMPTY/FULL DRUMS. DO NOT USE
ALUMINUM EQUIP OF STOR/TRANSFER. DO NOT ALLOW CONT W/ALUMINUM. VAPS
ARE HVR/AIR & WILL COLLECT IN LOW AREAS. CONT W/ALUMINUM PARTS IN A
PRESSURIZABLE FL UID SYS MAY CAUSE VIOLENT (SUPP DATA)

Exposure Controls

Respiratory Protection:WHERE VAP CONC EXCEEDS/IS LIKELY TO EXCEED 100
PPM, A NIOSH/MSHA APPRVD ORG VAP TYPE RESP IS ACCEPTABLE.
NIOSH/MSHA APPRVD SCBA/AIR LINE RESP W/FULL FACE PIECE IS REQD FOR
VAP CONC ABOVE 1,000 PPM & F OR SPILLS &/OR EMERGENCIES.
Ventilation:DO NOT USE IN CLSD/CONFINED SPACE, OPEN DOORS &/OR WINDOWS.
USE VENT TO MAINTAIN PROPER LEVELS. IF SPILL OCCURS (ING 6)
Protective Gloves:SOLV-RESISTANT GLOVES (VITON, (ING 7)
Eye Protection:CHEM WORK GOG & FULL LENGTH FSHLD.
Other Protective Equipment:SOLV-RESISTANT BOOTS, APRON, HEADGEAR &/OR
FSHLD SHOULD BE USED IF SPLASHING IS POSSIBLE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH: 9.7@10%. EFTS OF OVEREXP: TO EPINEPHRINE IN LAB ANIMALS & COULD
HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY
BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUT
ELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS . OTHER PREC: RXN.
CONSULT EQUIP SUPPLIER FOR FURTHER INFO. (ING 4)

Chemical Properties

HCC:T4
Boiling Pt:B.P. Text:>175F,>79C
Vapor Pres:124
Vapor Density:>1
Spec Gravity:1.075(H*2O=1)
pH:SUPDAT
Solubility in Water:NEGLIGIBLE
Appearance and Odor:LIGHT YELLOW, CITRUS ODOR.
Percent Volatiles by Volume:95

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, NITRATES, CHROMATES.
Stability Condition to Avoid:AVOID CONT W/OPEN FLAME, ELECTRIC
ARCS/OTHER HOT SURFACES WHICH CAN CAUSE THERMAL DECOMPOSITION.
Hazardous Decomposition Products:HYDROGEN CHLORIDE, PHOSGENE (SMALL
AMOUNTS).

Disposal

Waste Disposal Methods:RECOVERED LIQ MAY BE SENT TO A LICENSED
RECLAIMER/INCINERATION FACILITY. CONTAMD MATL MUST BE DISPOSED OF
IN A PERMITTED WASTE MANAGEMENT FACILITY. CONSULT FEDERAL, STATE
AND LOCAL DISPOSAL AUTHORITIE S FOR APPROVED PROCEDURES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.